SCHWEFELRÜCKGEWINNUNG: PROZESSANALYSATOREN
SRU Luftbedarfsanalysator
- H2S, SO2, COS, CS2
- Für alle SRU-Konfigurationen inkl. Kokereien
- Für alle Nachreinigungsprozesse
- Einfache Installation
- Geringer Wartungsaufwand, hohe Zuverlässigkeit, keine bewegten Teile
- Angepasstes CCD-UV-Spektrometer für schnelle und akkurate Messwerte
- Chemometrische Bestimmung aller Komponenten
- Kurze Prozessanbindung & spezielle Probenahmesonde = effiziente Schwefelvorabscheidung ohne Verstopfungsprobleme
- Luftbedarfsregelung
- Double Air Demand Kaskadenregelung
- Pitgas-Analyse
SCHWEFELRÜCKGEWINNUNG: TEMPERATURMESSUNG
Handheld Infrared Pyrometer, Claus
SRU Service
The CLAUSTEMP® Model HIP Handheld Pyrometer is a great tool for troubleshooting temperature measurement issues and calibrating Claus reactor pyrometers. Use it to look into furnace sight ports and pyrometer lens windows. Dual wavelength ratiometric measurement ignores flames, partial nozzle obstructions or moderately coated lens windows to accurately measure refractory temperature.
Operation and Technology
The HIP is a useful tool for troubleshooting temperature measurement problems and for calibrating process pyrometers in a Claus reactors.
It is designed to look into the optical window of most process pyrometers and sight ports of Claus reactors to read the hot face temperature.
The HIP pyrometer uses infrared wavelengths that are unaffected by combustion gases, allowing the pyrometer to measure refractory temperature while ignoring the effects of hot gases and flames. Dual wavelength sensing allows accurate temperature measurement even if the sight path is partially blocked by buildup or debris.
Features
- Measures refractory temperature
- Insensitive to reaction gas infrared radiation absorption and flame luminosity
- Multi-spectral measurement is accurate even if the sight path is partially
- Occluded
- Field of view identical to model HIR
- Accurate; 300 °C to 1700 °C range
- Compact, portable design with rugged case
Model HIR
Infrared Pyrometer, Claus SRU Service
Features
- Measures refractory temperature
- Insensitive to reaction gas infrared radiation absorption and flame luminosity
- Multi-spectral measurement is accurate even if the sight path is partially
- Occluded
- Field of view identical to model HIR
- Accurate; 300 °C to 1700 °C range
- Compact, portable design with rugged case
Specifications
- Range: 300 °C to 1700 °C (572 °F to 3092 °F)
- Accuracy: ± 11 °C (20 °F)
- Readout: High: Contrast LCD Display
- Output Signal: 4-20 mADC, 2 wire loop
- Loop Rating: Intrinsically safe when used with approved safety barriers
- Power Required: Powered by the 24 VDC loop
- Fiber Optic Cable: Flexible PTFE over SS armor; 3 meter (10 foot) is the standard length
- Approvals:
- Class I, Division 1, Groups B, C and D;
- Class II, Division 1, Groups E, F and G;
- Class III, Division 1
- Class I, Zone 1, Ex d IIB+H2
- Class I, Zone 1, AEx d IIB+H2
- II 2 G Ex d IIC T6 IP65 0575
- Hot Lens Mounting: On a flanged nozzle; steam jacketed 3” ANSI is standard, 2″ ANSI and other types and sizes available
- Housing Mounting: On a vertical surface or a 2” pipe stand with vertical or horizontal orientation
- Ambient Temperature Limits: Fiber Optics, Lens: -30 °C to +200 °C (-20 °F to 400 °F) Electronics: -15 °C to +65 °C (0 °F to 160 °F)
SCHWEFELRÜCKGEWINNUNG
BRIMSTONE STS Limited
Answers to your toughest sulfur recovery questions over 20 years
H2S- and H2Sx in Flüssigschwefel
Labor-Analysator-System
KOLORIMETRISCHE PROZESSANALYSATOREN
ProTech903™-Analysatoren mit Reaktionsband
Colorimetrisches Messprinzip (Hersteller: GALVANIC APPLIED SCIENCES INC., CALGARY, ALBERTA, KANADA)
- Protech903 H2S und GesamtschwefelAnalyzerH2S over-range capability, 5 ppbsensitivity level, Multi-stream capability ASTMD4084-94 & D4323-84, Total Sulfur capability (ASTM D4468-95). Zuverlässiger und genauer als alle anderen Messverfahren im kritischen Messbereich <15 ppmv. Interferenzfrei und matrixunabhängig.
- Protech903 Arsine Analyzer5 ppb sensitivity level, Multi-stream capabilityoptional permeation calibration deviceavailable.
- Protech903 Phosphine Analyzer 5 ppb sensitivity level, Multi-stream capability.
TUNABLE DIODE LASER ANALYZER
Prozessanalysatoren
ACCULASE-GPA™ TDL H2S ANALYZER
- 0 to 500 ppm H2S mit speziell entwickelter Messzelle und Technik
- Nachweisgrenze H2S = 0,15 ppm
- Selektive H2S-Messung ohne Methan, CO2, oder Benzininterferenz
- Benötigt kein Scrubbersystem
- Ansprechzeit 30 Sekunden
- Kann bis zu 4 Probenströme analysieren
In-line OR OPEN PATH Measurement
- Hoch selektiv und sensitiv
- Schnelle Ansprechzeit
- Multi-stream
- Fibre-optic
- Einfache on-touch-Kalibrierung
- Einfache Installation und Betrieb
- HF, NH3, CH4, H2O, HCL
SAMPLESYSTEME
Applikationsspezifische Samplesysteme
- Beispiel: LNG/ LPG-Verdampferstation
PIER ENTERPRISES GMBH & CO. KG
Obere Zeil 6-8
61440 Oberursel (Taunus)
Kontakt aufnehmen
Telefon: +49 (0) 617 18 87 560
Mail: info@pier-enterprises.net